Brew Panel Configurator

Menu
  • Vessel Configuration
  • HLT

    Control Type:

    Temp Sensor:

    Low Level Sensor:

  • MLT

    Control Type:

    Temp Sensor:

    Low Level Sensor:

  • Kettle

    Control Type:

    Temp Sensor:

    Low Level Sensor:

    High Level Sensor:

  •  
  • Controls Configuration
  • Panel Interface Type

  • Panel Finish

  •  
  • Accessory Controls
  • Remote EStops

    Accessory Relay Loads

    Additional Temp. Inputs (TS Only)

    Additional Control Channels (TS Only)

  • Accessories
  • Temperature Sensors

  • Thermowell RTD sensor

  • Plain RTD sensor

  • Pumps
  • Pump 1

    Pump Interface Type

    VFD Size

  • Pump 2

    Pump Interface Type

    VFD Size

  • Pump 3

    Pump Interface Type

    VFD Size

  • Pump 4

    Pump Interface Type

    VFD Size

  •  
  • Panel Details
 

Quote generated

Your quote has been generated.

Click the Download Quote button to view/download

Ok

Control Type Info

Monitor only

Provides means for monitoring the vessel only via RTD, display and web.

Outputs:

All outputs are relays rated 8A@110VAC. Nominal specs below are for circuit protection and may be adjusted as necessary. Higher power and multi-phase outputs available. Contact.

Steam (DC Solenoid)

Provides a DC output at nominal 1A@24VDC

Steam (AC Solenoid)

Provides an AC output at nominal 0.5A@110VAC

Thermostat (Contact closure)

Provides an isolated normally open relay contact. Typical ratings 8A@250V

Panel Control Interface Type

Standalone Controllers

Standalone industrial temperature controllers are industrial-quality, microcontroller-based temperature controllers with high-visibility LED displays, with PID and on/off modes. RS485 communication allows read/write to/from your controllers from our CuPID web interface.

Tcuchscreen / PLC Options

Our touchscreen/PLC combination option combines a user-friendly, industrial quality, IP-rated panel-mount touchscreen and a robust PLC control system to your panel. This combination offers the best in both control flexibility, web integration, and future-compatibility, should you wish to add more monitoring and control elements in the future. PLC programming also allows complex systems processing and output conditioning.

10", 17" 1280x800 Touchscreens

Our touchscreens are die-cast aluminum, IP65/NEMA4 industrial quality standalone units manufactured for durability and rugged operation.

Panel Finish Info

Grey Paint

NEMA4 rated panel with grey paint finish

Stainless Steel

Stainless Steel enclosure, resistant to caustic, NEMA 4X rating (available soon)

Request Formal Quote

Submit Quote Request
 

Pump Interface Type

On/off with contactor and starter

Internal panel contactor and motor starter

External VFD, no front panel controls

Washdown-duty rated VFD, controls on front panel of VFD.

External VFD with speed and on/off front panel controls

Washdown-duty rated VFD, with speed and on/off controls on brewpanel.

External VFD with speed, on/off, and fwd/rev front panel controls

Washdown-duty rated VFD, with speed, on/off and fwd/rev controls on brewpanel.

Level Sensors

Mechanical

304SS Mechanical level floats are the simplest and most cost-effective option, but have moving parts that will eventually fail, and can clog with brewing materials. Sensors also require clearance for a deflection on fill that indicates level. Sensors have a 1/2" NPT fitting easily coupled to a 1.5" TC adapter.

Optical

304SS/Polysulphone optical level sensors are a robust solution that requires immersion in fluid to indicate level. These may be placed in tees in existing fittings, making them ideal for retrofit. NPN/PNP output requires internal panel relay. Sensors have a 1/2" NPT fitting easily coupled to a 1.5" TC adapter.

Thermal

304SS Thermal level sensors are a versatile sensor that measures the thermal response of fluid, and may be calibrated on site for a variety of fluid types, such as foam vs. liquid, different liquid types, etc. Also comes with an internal mechanical relay that makes retrofit optimal by placing them inline with existing components. Sensors have a 1/2" NPT fitting easily coupled to a 1.5" TC adapter.

Thermal Level

316/204SS Thermal level sensor are ideal for measuring non-liquids such as foam and powder. This feature makes it ideal for detecting foam-over in brewing applications. NPN/PNP output requires internal panel relay, and is typically used with a timer in Kettle applications. Fitting is 1" NPT.

Timer Option

Internal on/off timers add process stability by adding delay for level switching output. In a Kettle boil, for example, bubbles and intermittent level changes may trip level sensors momentarily. This is especially problematic for direct and indirect fire systems, which can/should not be cycled rapidly. For standard controller systems, adjustable rail-mount timers offer tunable options for level sensing.
Touchscreen systems automatically include timers on all level sensors.

Pumps Size

VFD Size

Rating of VFD. VFDs up to 3HP support single and three-phase. 5HP and larger are run from three-phase electrical service.

Remote EStops

Remote Estop

For controls disable off of the brew deck (or wherever you like), we offer a remote Emergency Stop unit. Price here includes internal connections, external wiring, and commissioning.

Accessory Loads

Accessory Loads

Accessory loads provide contact closures (and power upon request) for external items such as lights, stack vents, etc. Typically, these loads are much more simpler and cost effective to add to a touchscreen system, which inputs and outputs can very easily be added to, with buttons added to your touchscreen interface.

Standard controllers options

Includes a lit LED pushbutton and relay are provided to control the load and indicate when it is activated

Touchscreen/PLC options

Includes a button on your touchscreen interface to control your load, with appropraite labeling

Add. PLC Temp. inputs

Add. PLC Temp. inputs (TS Only)

Additional temperature inputs for your teouchscreen/PLC system allow you to view temperatures of other site elements, such as additional vessel location temperatures, chiller lines, cold storage, grants -- anything you can attach a sensor to.

These work with any RTD sensor. We stock standard thermowell 1.5" TC sensors as well as small-barrel 4mm x 50mm waterproof RTD sensors (listed below) for use with these inputs.

Included in this option is sensor wiring (if desired), an additional hardware input (if necessary), read code for your PLC, and addition of a temperature display to your interface.

Add. Control Channels

Add. Control Channels (TS Only)

Additional control channels allow you to control temperature systems such as fermentation vessels, brite tanks, ceiling vents, recirculation pumps, or anything else with an input and an output -- we can make most anything fit your needs.

Typically, this option is the combination of an external load output with an additional temperature input. This option includes all temperature input options as the temperature input option above, an accessory relay output, wiring, and programming for PID, on/off, or whichever algorithm is desired.

Add. Temp Sensors

Thermowell RTD Sensor

Class A Pt100 RTD, Aluminum control head, 1/2" NPT Process Fitting, 3/4" NPT cable entry fitting

1.5" TC RTD Sensor

Class A Pt100 RTD, Aluminum control head, 1.5" TC Process Fitting, 3/4" NPT cable entry fitting

Temp Sensor

Sensor Types

Controls are designed for Platinum RTD inputs, which is what we offer.
Our standard RTD is sealed into an 8" thermowell, with a strain relief and 20' cable.
Thermoweell is attached to a 1.5" tri-clamp fitting.

Copyright 2016 Interface Innovations